Data Item Types: SAMPLE

From MTConnect® User's Portal
Jump to: navigation, search
Data Item type/subtype Description Units
ACCELERATION Rate of change of velocity MILLIMETER/SECOND^2
ACCUMULATED_TIME The measurement of accumulated time associated with a Component SECOND
ANGULAR_ACCELERATION Rate of change of angular velocity DEGREE/SECOND^2
ANGULAR_VELOCITY Rate of change of angular position DEGREE/SECOND
AMPERAGE The measurement of AC Current or a DC current AMPERE
ALTERNATING The measurement of alternating current. If not specified further in statistic, defaults to RMS Current AMPERE
DIRECT The measurement of DC current AMPERE
ANGLE The angular position of a component relative to the parent DEGREE
ACTUAL The angular position as read from the physical component DEGREE
COMMANDED The angular position computed by the Controller DEGREE
AXIS_FEEDRATE The feedrate of a linear axis MILLIMETER/SECOND
ACTUAL The actual federate of a linear axis MILLIMETER/SECOND
COMMANDED The feedrate as specified in the program MILLIMETER/SECOND
OVERRIDE The operator’s overridden value. Percent of commanded PERCENT
CLOCK_TIME The reading of a timing device at a specific point in time. Clock time MUST be reported in W3C ISO 8601 format YYYY-MM-DDThh:mm:ss.ffff
CONCENTRATION Percentage of one component within a mixture of components PERCENT
CONDUCTIVITY The ability of a material to conduct electricity SIEMENS/METER
DISPLACEMENT The displacement as the change in position of an object MILLIMETER
ELECTRICAL_ENERGY The measurement of electrical energy consumption by a component WATT_SECOND
FILL_LEVEL The measurement of the amount of a substance remaining compared to the planned maximum amount of that substance PERCENT
FLOW The rate of flow of a fluid LITER/SECOND
FREQUENCY The measurement of the number of occurrences of a repeating event per unit time HERTZ
LENGTH The length of an object MILLIMETER
STANDARD The overall length of an object MILLIMETER
REMAINING The remaining length of an ojbect MILLIMETER
USEABLE The useable length of an object MILLIMETER
LINEAR_FORCE The measure of the push or pull introduced by an actuator or exerted on an object NEWTON
LOAD The measurement of the percentage of the standard rating of a device PERCENT
MASS The measurement of the mass of an object(s) or an amount of material KILOGRAM
PATH_FEEDRATE The feedrate of the tool path MILLIMETER/SECOND
ACTUAL The three-dimensional feedrate derived from the Controller MILLIMETER/SECOND
COMMANDED The feedrate as specified in the program MILLIMETER/SECOND
OVERRIDE The operator’s overridden value. Percent of commanded PERCENT
PATH_POSITION The current program control point or program coordinate in WORK coordinates. The coordinate system will revert to MACHINE coordinates if WORK coordinates are not available MILLIMETER_3D
ACTUAL The position of the Component as read from the device MILLIMETER_3D
COMMANDED The position computed by the Controller MILLIMETER_3D
TARGET The target position for the movement MILLIMETER_3D
PROBE The position provided by a probe MILLIMETER_3D
PH The measure of the acidity or alkalinity PH
POSITION The position of the Component. Defaults to MACHINE coordinates MILLIMETER
ACTUAL The position of the Component MILLIMETER
COMMANDED The position as given by the Controller MILLIMETER
TARGET The target position for the movement MILLIMETER
POWER_FACTOR The measurement of the ratio of real power flowing to a load to the apparent power in that AC circuit PERCENT
PRESSURE The force per unit area exerted by a gas or liquid PASCAL
RESISTANCE The measurement of the degree to which an object opposes an electric current through it OHM
ROTARY_VELOCITY The rotational speed of a rotary axis REVOLUTION/MINUTE
ACTUAL The rotational speed the rotary axis is spinning at. ROTARY_MODE MUST be SPINDLE REVOLUTION/MINUTE
COMMANDED The rotational speed as specified in the program REVOLUTION/MINUTE
OVERRIDE The operator’s overridden value. Percent of commanded PERCENT
SOUND_LEVEL Measurement of a sound level or sound pressure level relative to atmospheric pressure DECIBEL
NO_SCALE No weighting factor on the frequency scale DECIBEL
A_SCALE A Scale weighting factor. This is the default weighting factor if no factor is specified DECIBEL
B_SCALE B Scale weighting factor DECIBEL
C_SCALE C Scale weighting factor DECIBEL
D_SCALE D Scale weighting factor DECIBEL
SPINDLE_SPEED DEPRECATED in REL 1.2. Replaced by ROTARY_VELOCITY -
ACTUAL The rotational speed of a rotary axis. ROTARY_MODE MUST be SPINDLE REVOLUTION/MINUTE
COMMANDED The rotational speed the as specified in the program REVOLUTION/MINUTE
OVERRIDE The operator’s overridden value. Percent of commanded PERCENT
STRAIN Strain is the amount of deformation per unit length of an object when a load is applied PERCENT
TEMPERATURE The measurement of temperature CELSIUS
TILT A measurement of angular displacement MICRO_RADIAN
TORQUE The turning force exerted on an object or by an object NEWTON_METER
VOLT_AMPERE The measure of apparent power in an electrical circuit VOLT_AMPERE
VOLT_AMPERE_REACTIVE The measurement of reactive power in an AC electrical circuit VOLT_AMPERE_REACTIVE
VELOCITY The rate of change of the position of a componenet MILLIMETER/SECOND
VISCOSITY The measurement of a fluid's resistance to flow PASCAL_SECOND
VOLTAGE The measurement of electrical power between two componenets VOLT
ALTERNATING The measurment of alternating current voltage VOLT
DIRECT The measurement of direct current voltage VOLT
WATTAGE The measurement of power consumed or dissipated by an electrical circuit or device WATT